		| Paper: | 
		Radiation test results on TK 1024 CCDs | 
	 
	
		| Volume: | 
		8, CCDs in Astronomy | 
	 
	
		| Page: | 
		275 | 
	 
	
		| Authors: | 
		Delamere, Alan; Murata-Seawalt, Debbie; Orbock, Jeff; Blouke, Morley; Fowler, Walt; Rebar, Frank | 
	 
	
	
		| Abstract: | 
		Results are presented from tests on TK 1024 CCDs with a multipinned phase (MPP) implant built into an experiental mask set. The average dark current as a function of temperature increased by a factor of about 3 for the 5 krads of gammas, which is a 10-fold increase for the extra 2 krads of protons. Histograms of the dark current show two types of dark current, an average level change, and dark current spikes. | 
	 
	
		| 
			
			
		 | 
	 
	
		  | 
	 
 
					 
				 | 
				  |